CBBWY - FIBERGLASS CLEANER, 131810
- MSDS: CBBWY
- Manufacturer: KEARNEY NATIONAL CO
- Product Name: FIBERGLASS CLEANER, 131810
- National Stock Number: 6850-00N035405
Product Identification
Product ID:FIBERGLASS CLEANER, 131810
MSDS Date:05/12/1993
FSC:6850
NIIN:00N035405
MSDS Number: CBBWY
Responsible Party
US
Emergency Phone: 419-384-3241
Info Phone: 404-939-6011
Cage: IO397
Contractor
Telephone: 404-939-6011
Cage: IO397
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 55-60%
OSHA PEL N/K
ACGIH TLV: N/K
KEROSENE
CAS: 8008-20-6
RTECS: OA5500000
Fraction By Weight: 23%
OSHA PEL N/K
ACGIH TLV: N/K
DOW CORNING 200 FLUID; (SILICONE)
CAS: 63148-62-9
RTECS: JJ6484500
Fraction By Weight: 1.0%
OSHA PEL N/K
ACGIH TLV: N/K
GLYCEROL; (GLYCERINE)
CAS: 56-81-5
RTECS: MA8050000
Fraction By Weight: 3.0%
OSHA PEL 15 MG/M3 (MIST)
ACGIH TLV: 10 MG/M3 (MIST)
SILICA, CRYSTALLINE-TRIPOLI-; (TRIPOLI)
CAS: 1317-95-9
RTECS: VV7336000
Fraction By Weight: 7.4%
OSHA PEL N/K
ACGIH TLV: N/K
SNOW FLOSS
Fraction By Weight: 5.0%
OSHA PEL N/K
ACGIH TLV: N/K
SUPER FLOSS
Fraction By Weight: 2.5%
OSHA PEL N/K
ACGIH TLV: N/K
MORPHOLINE
CAS: 110-91-8
RTECS: QD6475000
Fraction By Weight: 0.9%
OSHA PEL 20 PPM, S
ACGIH TLV: 20 PPM, S
PHENOL (SARA 302/313) (CERCLA)
CAS: 108-95-2
RTECS: SJ3325000
Fraction By Weight: 0.1%
OSHA PEL 5 PPM, S
ACGIH TLV: 5 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
STEARIC ACID
CAS: 57-11-4
RTECS: WI2800000
Fraction By Weight: 1.5%
OSHA PEL N/K
ACGIH TLV: N/K
BENZENE, O-DICHLORO-; (ORTHENE) (SARA 313) (CERCLA)
CAS: 95-50-1
RTECS: CZ4500000
Fraction By Weight: 0.5%
OSHA PEL 50 PPM, C
ACGIH TLV: 25 PPM; 50 STEL
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION: NONE KNOWN. INGESTION:
NONE KNOWN. SKIN: MAY CAUSE IRRITATION, REDNESS, DRYING. EYES: MAY
CAUSE IRRITATION, TEARING. CHRONIC: NONE KNOWN.
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-TRIPOLI: IARC
MONOGRAPHS, SUPP, VOL 7, PG 347, 1987:GROUP 2A. NTP 7TH ANNUAL
REPORT ON (SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE: FLUSH EYE WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES; SEEK MEDICAL ATTENTION. SKIN: WASH WITH MILD SOAP AND
WATER. INHALATION: REMOVE TO FRESH AIR. INGESTION: DO NOT INDUCE
VOMITING; SEE K IMMEDIATE MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:CARBON DIOXIDE, WATER SPRAY, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:STOP SPILL, WIPE UP OR ABSORB WITH INERT
MATERIAL.
Neutralizing Agent:NOT APPLICABLE.
Handling
Handling and Storage Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN
USE. KEEP PRODUCT FROM FREEZING.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NONE. USE NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:GENERAL VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH @ 1: SOLUTION: UNKNOWN; PH AS DISTRIBUTED: 8.8-9.1. EXPLAN OF
CARCIN: CARCINOGENS, ANTICIPATED TO BE CARCINOGEN. TARGET
ORGAN:LUNGS.
Chemical Properties
Spec Gravity:1.048 (H*2O=1)
pH:SUPDAT
Solubility in Water:INFINITE
Appearance and Odor:THICK, CREAMY WHITE LIQUID.
Percent Volatiles by Volume:80
Stability
Stability Indicator/Materials to Avoid:YES
UNKNOWN.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:UNKNOWN.
Disposal
Waste Disposal Methods:IN ACCORDANCE TO FEDERAL, STATE AND LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.